Causes of steel structure damage and reinforcement technical measures

When the steel structure is also damaged, we need to find the immediate solution to the problem. The main factors that describe the damage of the steel structure are: 1) due to load changes, overtime service, changes in specifications and procedures, resulting in insufficient structural bearing capacity; 2) components Deformation, distortion, disability, depression, etc. due to various accidents, resulting in weakened section of the member, warpage of the member, joint cracking, etc.; 3) deformation or cracking of the member or joint under temperature difference; 4) due to chemical substances Corrosion caused by corrosion and electrochemical corrosion caused the structural section of steel structural members to weaken; 5) Others include errors in design, production, construction, and illegal use and operation during service.

There are three main technical measures for reinforcement of steel structures: 1) Cross-section reinforcement method: reinforcement of steel in part or along the entire length of the member, and jointing to make it work together; 2) Change calculation sketch: add additional support, adjust Load distribution, reduce internal force level, force displacement of statically indeterminate structural support, reduce stress peak; 3) Prestressed cable method: use high-strength cable to strengthen structural weak link or improve overall bearing capacity, stiffness and stability of structure .

    Our company manufactures the finest range of Hot Dip Galvanized Ladder Type Cable Trays is suited for heavy weight cables. These cables have the capacity to carry multi network cables without any complication. Our cable trays are accurate in dimensions and have longer life in comparison to other types of cable trays. These are easily assembled and attached to floor, wall, ceiling or top of racks.
 
    Features :
High tensile strength
Sturdy construction
Dimensional accuracy
Easy to assemble & install
Sturdy built
Corrosion free
Low maintenance
Attach to floor, ceiling, wall or top of rack & cabinets
Available in several widths, heights and lengths
Support large quantity of network cables
Cut & form smooth curved transitions around obstacles
Install quickly using drop in support
Applications
Shopping malls
Hotels
Railways
Airports
Hospitals
Residential complexes
Commercial buildings
Industries
Product Details:
Length 1000/2440/3000/6000 mm
High 50-150 mm
Side Rail Height 50-300 mm
Max. Working Load 1000 KG
Cable Tray Coating Galvanized Coating
Material Steel, Stainless Steel
Tray Type Ladder Type Cable Tray

Hot-Galvanized Ladder Cable Tray

Hot-Galvanized Ladder Cable Tray,Hot-Galvanized Cable Tray,Hot-Galvanized Cable Ladder

Yangzhong Huaxin Power Equipment Co.,Ltd , http://www.huaxinbusbarchina.com