There are four common vane pump failure, the solution is simple. First, no pressure difference (1) vane pump steering wrong, check the steering; (2) medium dirty leaves by the main card: dial drive shaft, positive and negative turn a few times so that the pump blade activity, still not on the pressure, then Check the valves, open the outlet pipe, the gas discharge from the outlet; Second, the working pressure of up to Less than (1) speed is too low. Appropriate increase speed; (2) seal a large number of leaks, first check whether the bearing is damaged, if not bad, check the oil seal and replace; (3) safety valve opening pressure is too low, adjust the safety valve plug to meet the required pressure; (4) Loss is too large, the main parts of the vane pump such as: eccentric pump cover, end caps, rotors, blades and other wear is too large then replace the parts; Third, vibration and noise (1) bearing damage, replace the bearing; Heart and drive shaft is not the same, the offset is too large, adjust the pump shaft and drive shaft concentricity, so that the tilt angle of not more than 7 degrees; (3) Vane pump foot loose, fastening oil pump anchor bolts; (4) Eccentric Set of wear and tear is too large, replace the eccentric sleeve; four double pump changes difficult, gear not on (1) the pressure is too low or electromagnetic valve failure, increase the pressure or replace the Solenoid Valve; (2) Flexible, adjusted and lubricated or replaced.